Confirm how backup mode starts
Cut mains power in the intended circuit and record when the bulb changes to battery light, including the required wall-switch position.

Image 1 of 7
EMERGENCY RECHARGEABLE LED BULB
This bulb combines normal lighting with a rechargeable backup function and a listed two-removable-battery option. Verify the exact battery pack, charging instructions, emergency brightness and runtime on a sample.
PRODUCT DETAILS
PRODUCT DETAIL & BUYER BRIEF
Test normal light and battery-backed operation separately in the intended socket and switch arrangement.
Cut mains power in the intended circuit and record when the bulb changes to battery light, including the required wall-switch position.
Follow the model's charging instructions before the first outage test and record the starting charge condition.
Record the light level in each mode on the same sample; do not treat the normal-light rating as the backup rating.
Run the fully charged sample under agreed switch and light conditions; record duration alongside emergency brightness and battery arrangement.
Check the return to normal lighting and charging indication, then repeat an outage test after recharge or storage if relevant.
Check battery type, inclusion, replacement guidance and pack instructions against the quoted selling unit.
Put battery, charging conditions, emergency light level and measured runtime on the same approved sample record and quote.
Ask how the quoted battery is charged in normal use and follow the offered instructions before a first backup test. After long storage, recharge and retest as directed for the model. Compare emergency brightness and duration under the same stated conditions; capacity alone does not show usable backup light.
OEM & PRIVATE-LABEL OPTIONS
HAVE A PRODUCT IN MIND?
Send the base, voltage, normal power, battery arrangement, desired emergency brightness and runtime, quantity, packaging and instruction requirements.